Field guide
Five rules and every dial position.
Nine positions, four jacks. Learn what each one measures, which lead goes where, and the rules that keep the meter alive.
The golden rules
Black never moves
COM is home. The black lead stays there for every measurement on the DW-100.
Ω needs a dead circuit
Resistance, continuity and diode test supply their own voltage. Any live circuit corrupts the reading and can destroy the meter.
Current goes through, not across
Break the circuit and put the meter in the path. Across a supply, current mode is a dead short.
Match the jack to the job
VΩ for volts, ohms and diodes. mA for small current. 10A for heavy current, briefly.
Check the dial before you trust it
The last person's setting is not your setting. Dial and jacks first, every single time.
The jacks
The black lead lives here. It is the common reference for every measurement.
Red lead for volts, ohms, continuity, diode and capacitance.
Red lead for small current, in series, with its own fuse inside the meter.
Red lead for heavy current only. Often unfused, so keep the test brief.
Voltage
2 positionsDC voltage
red → VΩSteady voltage from batteries, adapters and DC rails.
typical 12.47 V DC
AC voltage
red → VΩMains, transformer secondaries and anything that alternates.
typical 120.4 V AC
Resistance and continuity
3 positionsResistance
red → VΩComponent values and opens, measured with the circuit dead.
typical 9.87 kΩ
Continuity
red → VΩBeeps on a closed path: fuses, switches, wire runs.
typical 0.004 Ω
Diode test
red → VΩForward drop of a junction, and which way it conducts.
typical 0.613 V
Current
2 positionsMilliamps
red → mASmall circuit current, in series through the mA jack.
typical 18.6 mA
Amps
red → 10AHeavier loads. Red lead moves to the 10 A jack.
typical 2.84 A
Everything else
2 positionsPower off
Dial parked. Nothing is measured and nothing drains the battery.
typical — — — off
Capacitance
red → VΩFarads: motor start caps, filter caps, timing caps.
typical 46.8 µF
Before you touch anything
- Voltage is measured across a component, with the circuit live.
- Resistance and continuity need the circuit dead and the part isolated.
- Current is measured in series: break the circuit and put the meter in the path.
- Check the jacks before you power up. The wrong jack on a live rail blows the fuse.